Venue Information
Floor Size
- 136’ x 213’
Ceiling Height
- Roof Height: 98’
- Lower Chords of Roof Trusses: 73’
- Bottom of Scoreboard: 63’8”
House Curtain System
- Half House
- Stage Side masking
- Upper Bowl Masking
Backstage
- Four (4) Dressing Rooms
- Two (2) Production Offices
- One (1) Media Press Room
Load in/Out Parking
- Two (2) loading docks
- One (1) drive-in bay with access to Marshalling area and arena event floor
- Marshalling Area 3260 square feet
- 1500 dedicated on-site parking spaces
Ticket Office
- Full – service ticket office providing computerized ticketing, remote outlets and telephone order service for all events.
Telephones/Internet
- Wireless Internet will be provided in arena
- Hardware Internet access is available
Rigging Guidelines
Spotlights
- Four (4) 3,000 watt and two (2) 2,000 watt
Show Labor
- Show labor provided by Stagemonkie, LLC
- Contact: William "Jason" Moore
- stagemonkie@stagemonkie.com
Power Information
Stage Right Show Power
(lighting, rigging, lasers, miscellaneous)
(lighting, rigging, lasers, miscellaneous)
- (3) 400A, 208/120V, 3 phase with a 400A main circuit breaker
- (1) 200A, 208/120V, 3 phase with a 200A main circuit breaker
- (1) 400A, 208Y/120V, 3 phase with a 400A main circuit breaker
- (1) 800A, 208Y/120V, 3 phase with an 800A main circuit breaker
Stage Left Show Power (sound)
- (1) 200A, 208/120V, 3 phase with a 200A main circuit breaker
- (1) 600A, 208/120V, 3 phase with a 600A main circuit breaker
Event Floor North
- (1) 200A, 208/120V, 3 phase with a 200A main circuit breaker
Event Floor South
- (1) 200A, 208/120V, 3 phase with a 200A main circuit breaker
Event Floor West
- (1) 400A, 208Y/120V, 3 phase with a 400 a main circuit breaker
Service Court Pedestals
- (3) 100A, 208/120V, 3 phase with (1) 20A, 125V receptacle (Nema 5-20R), (1) 30A, 125V receptacle (Nema 5-30R) and (1) 50A, 125/250V receptacle (Nema 14-50R)
- (1) 200A, 208/120V, 3 phase with a 200A main circuit breaker and (2) 100A Helox receptacles
- (3) 400A, 208Y/120V, 3 phase with a 400 a main circuit breaker and (2) 200A Helox receptacles
- (1) (at satellite uplink) 225A, 208/120V, 3 phase with (2) 100A, 3ph. 5 wire receptacles (Female 5-Pin sleeve receptacle) , (2) 50A 1ph., 2 pole, 3 wire receptacles (Nema 6-50R), (2) 30A 1ph., 2 pole, 3 wire receptacles (Nema L6-30R), and (2) 20A duplex receptacles (Nema 5-20R)
Seating Configurations
Please note – the seating configurations may vary based on production requirements.
- Basketball
- Basketball Alternate
- Center Stage
- Center Stage w/ Upper Masking
- Circus
- End Stage 180
- End Stage 180 w/ Upper Masking
- End Stage 270
- End Stage 270 w/ Upper Masking
- End Stage 360
- End Stage 360 w/ Upper Masking
- End Stage 360 Alternate
- End Stage 360 Alternate w/ Upper Masking
- Floor Event
- Floor Event w/ Upper Masking
- Half House
- Half House w/ Upper Masking
- Quarter House
- Quarter House w/ Upper Masking
- Quarter House w/ Stage-Side Masking
- Quarter House w/ Stage-Side and Upper Masking